Award

Los Angeles County Internal Services Department PO-IS-26008134

Annual inspection and maintenance services for Fulton Split Deaerator and Condensate Tank by California Boiler Inc.

Recipient

CALIFORNIA BOILER INC

Award Amount

$68,483.00

Ceiling

$68,483.00

Awarded

April 07, 2026

Identifier

PO-IS-26008134

The Los Angeles County Internal Services Department issued a purchase order to California Boiler Inc. for annual inspection, cleaning, and minor maintenance of a Fulton Split Deaerator and Condensate Tank, including internal visual inspection, cleaning, and replacement of parts. The order includes multiple line items such as the main inspection service, overtime labor for boilermaker and mechanic, trip charges, and replacement parts. The total obligated amount is $68,483. The work is scheduled for April 2026 and is performed at a facility in Los Angeles, California. The procurement aims to ensure system reliability and safety through scheduled maintenance during outages.

Description

ANNUAL INSPECTION ON (1) FULTON SPLIT DA TANK $2,700 - $1,962.89 (Customer Discount) = $737.11 Control Technician 1 Overtime [Boiler Water System] Location - Building Scope of Work -Annual DA Tank Inspection (1) Fulton Split Deaerator & Condensate Tank Schedule - Customer Shutdown: Friday 10:00 PM - California Boiler: 11 :00 PM -7:00 AM (8 hrs) - System Required Online: Saturday 8:00 AM Work Scope: - Verify system is shut down, drained, and safe for entry - Set up confined space, lighting, and ventilation - Open both sides of DA tank and remove manways/gaskets - Internal visual inspection of DA & condensate tank (corrosion, scale, condition) - Inspect spray head and internal components - Take photos and provide condition report - Sweep debris and water wash/flush tanks (leave drains open) - Replace sight glass and valves - Open and clean Y-strainers and inspection piping - Re-gasket and reassemble all openings - Leave system ready for startup Annual inspection and cleaning of the deaerator and condensate tank to maintain reliability and identify potential issues. Service includes confined space entry, internal inspection, cleaning, minor maintenance, and reporting. Work is performed during scheduled outage and coordinated for timely return to service. Quote #21411 Requestor: Rafael Oganesyan 213-974-9504; Boilermaker Overtime; Mechanic Overtime; LA-03 - Trip Charge; GASKET, MH 12X16X1-1/4 (E) (TOPOG-E) T12X16X1 .25; VALVE, SIGHTGLASS 1/2 SET (CONBRACO) 20-351-03; SIGHTGLASS, REDLINE 5/8X36 (HEAVY WALL) .625X36HW