Award

Springfield-Greene County Park Board 230421

JORDAN VALLEY ICE PARK ANNUAL FIRE ALARM INSPECTIONS & REGULATORY COMPLIANCE PAPERWORK FEE; FIELDHOUSE SEMI ANNUAL KI...

Recipient

360 FIRE PROTECTION LLC

Award Amount

$24,217.50

Ceiling

$24,217.50

Awarded

July 18, 2025

Identifier

230421

Description

JORDAN VALLEY ICE PARK ANNUAL FIRE ALARM INSPECTIONS & REGULATORY COMPLIANCE PAPERWORK FEE; FIELDHOUSE SEMI ANNUAL KITCHEN SYSTEM INSPECTION & TANDEM TANK INSPECTION, REPL (6) FUSIBLE LINKS; BOTANICAL CENTER ANNUAL FIRE ALARM INSPECTION & REGULATORY COMPLIANCE PAPERWORK FEE; FIELDHOUSE PRIVATE FIRE HYDRANT INSPECTION & COMPLIANCE UPLOAD FEE; RIVERCUT GOLF COURSE SEMI ANNUAL KITCHEN SYSTEM INSPECTION & FUSIBLE LINK (3); DAN KINNEY FAMILY CENTER ANNUAL FIRE EXTINGUISHER INSPECTION (8), ANNUAL EXIT/EMERGENCY LIGHT INSPECTIONS (19), AND ANY REPAIRS NEEDED; CHESTERFIELD FAMILY CENTER ANNUAL BACKFLOW TEST & INSPECTION, REGULATORY COMPLIANCE PAPERWORK FEE, REPAIRS NEEDED, SERVICE CALL; FIELDHOUSE ANNUAL BACKFLOW INSPECTION, SERVICE CALL, REGULATORY COMPLIANCE PAPERWORK FEE, BACKFLOW LABOR & REPAIRS; BOTC ANNUAL BACKFLOW INSPECTION, SERVICE CALL, REGULATORY COMPLIANCE PAPERWORK FEE, BACKFLOW LABOR & REPAIRS; expires 06/30/26.; COOPER TENNIS REPAIRED GROUND FAULT AFTER REMOVING COMPROMISED WIRE FROM THE SYSTEM; CHESTERFIELD FAMILY CENTER REPLACED ALL LOADED & CORRDODED SPRINKLER HEADS (31), REFILLED SYSTEM, CLEANED ALL DUSTY SPRINKLER HEADS, REPLACED 3 CHROME ESCUTCHEONS, LABOR & SERVICE CALL; BOTANICAL CENTER LATE FEES; SPRINGFIELD SKATE PARK SERVICE CALL, REGULATORY COMPLIANCE PAPERWORK FEE, ELECTRIC BELL INSTALLED & CHROME 155 SIDEWALL, SPRINKLER LABOR; COOPER TENNIS SERVICE CALL, NEW EMERGENCY LIGHT UNIT (15), NEW EXIT LIGHT UNIT (5), BATTERIES (11), LABOR; RUTLEDGE WILSON ANNUAL FIRE EXTINGUISHER INSPECTION (10), CABINET, NEW FIRE EXTINGUISHER, REPAIRS NEEDED; BOTANICAL CENTER SERVICE CALL; SPRINGFIELD GREENE PARK BOARD FIRE EXTINGUISHER ANNUAL INSPECTION (4); FIELDHOUSE ANNUAL FIRE ALARM INSPECTION & REGULATORY COMPLIANCE PAPERWORK FEE; JORDAN VALLEY ICE PARK SERVICE CALL, REGULATORY COMPLIANCE PAPERWORK FEE, REPAIRS COMPLETED 4" MAIN, 2-1/2" BRANCH AND ACCELERATOR FOR WEST RINK SYSTEM; JORDAN VALLEY ICE PARK ANNUAL EXIT/EMERGENCY LIGHT INSPECTIONS (32), ANNUAL FIRE EXTINGUISHER INSPECTION (21), AND REPAIRS NEEDED; COOPER TENNIS SERVICE CALL, SPECIAL ORDER BATTERIES FOR E-LIGHTS; CHESTERFIELD FAMILY CENTER ANNUAL FIRE EXTINGUISHER INSPECTIONS (14), ANNUAL EXIT/EMERGENCY LIGHT INSPECTIONS (40), REPAIRS NEEDED; DOLING FAMILY CENTER SEMI-ANNUAL KITCHEN SYSTEM INSPECTION, ANNUAL EXIT/EMERGENCY LIGHT INSPECTIONS (29), ANNUAL FIRE EXTINGUISHER INSPECTIONS (15), AND REPAIRS NEEDED; FIELDHOUSE DIAG FIRE TROUBLE & NAC 2 WIRES ISSUES. WERE DISCONNECTED UNTIL GROUND FAULT MUST BE LOCATED & RESOLVED BEFORE WIRES CAN BE RECONNECTED.; JORDAN VALLEY ICE PARK SERVICE CALL, NEW EXIT LIGHT W/BATTERY BACK UP (6); FIELDHOUSE REPAIR FACP; COOPER SOCCER PRIVATE FIRE HYDRANT INSPECTIONS (2) & COMPLIANCE UPLOAD FEE; COOPER TENNIS ANNUAL SPRINKLER INSPECTION, COMPLIANCE UPLOAD FEE, ANNUAL SPRINKLER DRY INSPECTION; FIELDHOUSE LOCATED SECOND GROUND FAULT BEHIND NAC IN COURT 4, REPLACED DEVICE (CUSTOMER PROVIDED); FIELDHOUSE DIAG & REPAIR GROUND FAULT LOCATED IN COURT 3; FIELDHOUSE SEMI-ANNUAL KITCHEN SYSTEM INSPECTION, TANDEM TANK INSPECTION, SYSTEM PUFF TEST, FUSIBLE LINK (6); HORTON SMITH GOLF COURSE MAINT BLDG ANNUAL FIRE EXTINGUISHER INSPECTION (7), AND ANY REPAIRS NEEDED; JORDAN VALLEY ICE PARK SYSTEMS BACK ONLINE & HAVE RETURNED TO NORMAL SERVICE, EMERGENCY SERVICE CALL & REPAIRS NEEDED; COOPER TENNIS 3 YEAR FULL TRIP TEST & AIR TEST, 20 YEAR UL HEAD TESTING, REGULATORY COMPLIANCE PAPERWORK FEE (2), SERVICE CALLS, AND REPAIRS NEEDED; SPARC JENNY LINCOLN PARK ANNUAL FIRE EXTINGUISHER INSPECTION (2), SERVICE CALL; COOPER SOCCER ANNUAL FIRE ALARM INSPECTIONS, REGULATORY COMPLIANCE PAPERWORK FEE, REPLACE BATTERIES (2); BOTANICAL CENTER ANNUAL SPRINKLER WET INSPECTION, COMPLIANCE UPLOAD FEE; COOPER TENNIS DIAG REQUIREMENTS FOR AIR COMPRESSORS SERVING DRY SPRINKLER SYSTEMS FOR FIRE PROTECTION USE, EMERGENCY SERVICE CALL; DAN KINNEY FAMILY CENTER ANNUAL FIRE ALARM INSPECTIONS, ANNUAL CELL BATTERY LOAD TEST, REPL (4) BATTERIES, REPLACE BREAKER LOCKS/DECAL, REGULATORY COMPLIANCE PAPERWORK FEE; DAN KINNEY FAMILY CENTER ANNUAL SPRINKLER WET INSPECTIONS (3), COMPLIANCE UPLOAD FEE (3)