# Orleans Parish 14954

REMOVAL AND DISPOSAL OF EXISTING PORTLAND CEMENT CONCRETE PA; REMOVAL AND DISPOSAL OF EXISTING SIDEWALK, DRIVEWAY, FO...

**Recipient:** Wallace C. Drennan, Inc.

**Award Amount:** $12,817,460.83
**Ceiling:** $12,817,460.83

**Awarded:** December 31, 2020

**Identifier:** 14954

### Description

REMOVAL AND DISPOSAL OF EXISTING PORTLAND CEMENT CONCRETE PA; REMOVAL AND DISPOSAL OF EXISTING SIDEWALK, DRIVEWAY, FOOT LA; REMOVAL AND DISPOSAL OF EXISTING CURB AND GUTTER BOTTOM; REMOVAL AND DISPOSAL OF EXISTING ASPHALTIC CONCRETE PAVEMENT; ROADWAY EXCAVATION; UNSUITABLE SUBGRADE EXCAVATION AND SAND FILLING; GEOTEXTILE FABRIC FOR STABILIZATION; GEOGRID; BASE COURSE; TRAFFIC MAINTENANCE AGGREGATE; SUPERPAVE ASPHALTIC CONCRETE BINDER COURSE FOR COMPOSITE ROA; 2.5” THICK SUPERPAVE ASPHALTIC CONCRETE WEARING COURSE; 4.5” THICK SUPERPAVE ASPHALTIC CONCRETE BINDER COURSE; COLD PLANING ASPHALTIC PAVEMENT (2.5" AVERAGE THICK); REINFORCED CONCRETE PAVEMENT (8" THICK); CONCRETE SIDEWALK (4" THICK); CONCRETE DRIVEWAY (6" THICK); LETTER OR NUMBER FOR TILE STREET NAME; BRICK SIDEWALK; RESETTING TILE STREET NAME; CONCRETE MOUNTABLE CURB AND GUTTER BOTTOM; 6" CONCRETE BARRIER CURB & GUTTERBOTTOM OR ROLLING STRIP; SIDEWALK, DRIVEWAY AND CURB SAW CUTTING; PAVEMENT SAW CUTTING ADJACENT TO EXISTING PAVEMENT AND AT PA; REMOVAL OF HANDICAP RAMPS, CURB AND GUTTER, AND CONCRETE SID; ADA-ACCESSIBLE CURB RAMPS, CURB AND GUTTER, AND CONCRETE SID; ROOT PRUNING; SURFACE APPLIED TACTILE / DETECTABLE WARNING SURFACE TILES; SINGLE VERTICAL CATCH BASIN REPAIR OR VERTICAL ADJUSTMENT RE; DOUBLE VERTICAL CATCH BASIN REPAIR OR VERTICAL ADJUSTMENT RE; SINGLE MOUNTABLE CATCH BASIN REPAIR OR VERTICAL ADJUSTMENT R; MANHOLE REPAIR OR VERTICAL ADJUSTMENT UP TO 6" REUSING EXIST; MANHOLE REPAIR OR VERTICAL ADJUSTMENT OVER 6" REUSING EXISTI; SIDEWALK TRANSITION ADJACENT TO HANDICAPPED RAMPS; SODDING; REPLACE EXIST. SEWER H.C. FROM NEW MAIN TO BACK OF CURB; REPLACE EXIST. SEWER H.H. BEYOND BACK OF CURB; PIPE LINER (CIPP, 8"); PIPE LINER (CIPP, 10"); PIPE LINER (CIPP, 12"); PIPE LINER (CIPP, 15"); PIPE LINER (CIPP, 18"); CUT LINER TO RESTORE EXISTING SEWER HOUSE CONNECTION (6", CI; MANHOLE COVER; MANHOLE FRAME; SEWER POINT REPAIR UP TO 12 FEET (8" AT 0' - 6.0'); SEWER POINT REPAIR UP TO 12 FEET (8" AT 6.1' - 8.0'); SEWER POINT REPAIR UP TO 12 FEET (8" AT 8.1' - 10.0'); SEWER POINT REPAIR UP TO 12 FEET (12" AT 10.1' - 12.0'); SEWER POINT REPAIR UP TO 12 FEET (15" AT 12.1' - 14.0'); SEWER POINT REPAIR UP TO 12 FEET (18" AT 14.1' - 16.0'); SEWER POINT REPAIR BEYOND 12 FEET (8" AT 6.1' - 8.0'); SEWER POINT REPAIR BEYOND 12 FEET (8" AT 8.1' - 10.0'); SEWER POINT REPAIR BEYOND 12 FEET (8" AT 12.1' - 14.0'); SEWER POINT REPAIR BEYOND 12 FEET (12" AT 10.1' - 12.0'); SEWER POINT REPAIR BEYOND 12 FEET (15" AT 12.1' - 14.0'); SEWER POINT REPAIR BEYOND 12 FEET (18" AT 14.1' - 16.0'); SEWER SERVICE LATERAL LINING (6" CIPP); MANHOLE REHABILITATION, CEMENTITIOUS LINER, PARTIAL DEPTH (2; MANHOLE REHABILITATION, CEMENTITIOUS LINER, FULL DEPTH; REPLACE 5/8" TO 1'' WATER HOUSE CONNECTION WITH 1'' WATER; REPLACE 1-1/2" WATER HOUSE CONNECTION (FROM MAIN TO METER); REMOVE MUD AND DEBRIS FROM INSIDE OF WATER METER BOX; ADJUST COMPLETE WATER METER BOX TO GRADE; REPLACE BROKEN WATER METER BOX (5/8") TO (1"); REPAIR WATER MAIN WITH FULL CIRCLE CLAMP (PIPE SIZE 4" - 8"; REPAIR WATER MAIN WITH FULL CIRCLE CLAMP (PIPE SIZE 12" - 16; REPAIR WATER MAIN WITH BELL JOINT REPAIR CLAMP (PIPE SIZE 4; REPAIR WATER MAIN WITH BELL JOINT REPAIR CLAMP (PIPE SIZE 12; REPAIR WATER MAIN BY REMOVE AND REPLACE - MINIMUM LENGTH 4 F; REPAIR WATER MAIN BY REMOVE AND REPLACE - BEYOND 10 FT, MAXI; REMOVAL AND DISPOSAL OF EXISTING CURB (CONCRETE, ASPHALT, BR; RELAYING BRICK SIDEWALK; CONCRETE MOUNTABLE CURB WITH DOWELS; 6" CONCRETE BARRIER CURB WITH DOWELS; PIPE LINER (CIPP, 21"); REMOVAL OF CAST IRON FLUSH VALVE APPARATUS FROM SEWER MANHOL; REMOVAL OF WATER SERVICE LINE FROM SEWER MANHOLE TO A DISTAN; LOCATION AND SELECTIVE REMOVAL OF WATER LINE FROM WATER MAIN; SEWER POINT REPAIR UP TO 12 FEET (8" AT 10.1' - 12.0'); SEWER POINT REPAIR UP TO 12 FEET (8" AT 12.1' - 14.0'); SEWER POINT REPAIR UP TO 12 FEET (10" AT 10.1' - 12.0'); SEWER POINT REPAIR UP TO 12 FEET (12" AT 8.1' - 10.0'); SEWER POINT REPAIR UP TO 12 FEET (21" AT 14.1' - 16.0'); SEWER POINT REPAIR BEYOND 12 FEET (8" AT 0' - 6.0'); SEWER POINT REPAIR BEYOND 12 FEET (8" AT 10.1' - 12.0'); SEWER POINT REPAIR BEYOND 12 FEET (10" AT 10.1' - 12.0'); SEWER POINT REPAIR BEYOND 12 FEET (21" AT 14.1' - 16.0'); EXCAVATION OEVER CIPP SEWER MAIN FOR SEWER HC TIE-IN; EXPLORATORY WORK; SANITARY SEWER BYPASS PUMPING SETUP/REMOVAL; SANITARY SEWER BYPASS PUMPING 30 DAYS OF OPERATIONS; SANITARY SEWER BYPASS PUMPING; 4.5âE THICK SUPERPAVE ASPHALTIC CONCRETE BINDE; SANITARY SEWER CLEANING/ CCTV; ADDITIONAL 8" [I,[ 30 DAYS OF OPERATION; ADDITIONAL BYPASS PUMPING SETUP/REMOVAL (8" PUMP); SEWER PT REPAIR UP TO 12 FT (12" AT 12.1' AND 14.0'); SEWER PT REPAIR UP TO 12 FT (10" AT 12.1' AND 14.0'); SANITARY SEWER BYPASS PUMPING SETUP/REMOVAL AND 30 DAYS OF O; SEWER MAIN HEAVY; Additional Bypass Pumping Setup/Removal (8" pump); ADDITIONAL 8" PUMP 30 DAYS OF OP; SEWER MAIN CLEANING; CONCRETE MOUNTABLE CURB WITH OR WITHOUT DOWELS (STRAIGHT, CI
