Orleans Parish 14959

REMOVAL AND DISPOSAL OF EXISTING PORTLAND CEMENT CONCRETE PA; REMOVAL AND DISPOSAL OF EXISTING SIDEWALK, DRIVEWAY, FO...

Recipient

DURR HEAVY CONSTRUCTION LLC

Award Amount

$5,687,831.40

Ceiling

$5,687,831.40

Awarded

December 31, 2020

Identifier

14959

Description

REMOVAL AND DISPOSAL OF EXISTING PORTLAND CEMENT CONCRETE PA; REMOVAL AND DISPOSAL OF EXISTING SIDEWALK, DRIVEWAY, FOOT LA; REMOVAL AND DISPOSAL OF EXISTING CURB (CONCRETE, ASPHALT, BR; REMOVAL AND DISPOSAL OF EXISTING ASPHALTIC CONCRETE PAVEMENT; ROADWAY EXCAVATION; UNSUITABLE SUBGRADE EXCAVATION AND SAND FILLING; GEOTEXTILE FABRIC FOR STABILIZATION; GEOGRID; BASE COURSE; TRAFFIC MAINTENANCE AGGREGATE; ASPHALTIC CONCRETE; 2 1/2" THICK SUPERPAVE ASPHALTIC CONCRETE WEARING COURSE; SUPERPAVE ASPHALTIC CONCRETE BINDER COURSE (7 1/2" THICK); COLD PLANING ASPHALTIC PAVEMENT (2 1/2" AVERAGE THICKNESS); REINFORCED CONCRETE PAVEMENT (9" THICK); SURCHARGE FOR HIGH EARLY STRENGTH; REINFORCED CONCRETE PIPE - (12" DIAM.); REINFORCED CONCRETE PIPE - (15" DIAM.); REINFORCED CONCRETE PIPE - (18" DIAM.); REINFORCED CONCRETE ARCH PIPE - (28" X 18 1/2"); REINFORCED CONCRETE PIPE - (21" DIAM.); REINFORCED CONCRETE ARCH PIPE - (36" X 22 1/4"); REINFORCED CONCRETE PIPE - (24" DIAM.); REINFORCED CONCRETE PIPE - (36" DIAM.); REINFORCED CONCRETE PIPE - (42" DIAM.); REINFORCED CONCRETE WYE OR ARCH (18" x 12"); REMOVAL & DISPOSAL OF EXISTING DRAIN LINES (NOT IN SAME TREN; NO 1. STANDARD DRAIN MH; NO 2. STANDARD DRAIN MH; NO 3. STANDARD DRAIN MH; SPECIAL DMH (SWB DWG 3340); COMBINATION CATCH BASIN & MANHOLE; NO.1 CATCH BASIN; SINGLE MOUNTABLE CATCH BASIN; 24" X 30" CLEAR OPENING STANDARD DROP INLET; ADJUST MH. OR DROP INLET UP TO 6" W/BRICK AND MORTAR; CONCRETE SIDEWALK (4" THICK); CONCRETE DRIVEWAY (6" THICK); CONCRETE DRIVEWAY (8" THICK); BRICK SIDEWALK; CONCRETE MOUNTABLE CURB WITH OR WITHOUT DOWELS (STRAIGHT, CI; 6" CONCRETE BARRIER CURB WITH OR WITHOUT DOWELS (STRAIGHT, C; 8" CONCRETE BARRIER CURB WITH OR WITHOUT DOWELS (STRAIGHT, C; CONCRETE MOUNTABLE CURB AND GUTTER BOTTOM; 6" CONCRETE BARRIER CURB & GUTTERBOTTOM OR ROLLING STRIP; POT HOLE REPAIR ON ACCESS ROUTES; PLASTIC PAVEMENT STRIPING (SOLID LINE)(4" WIDE); PLASTIC PAVEMENT STRIPING (SOLID LINE)(6" WIDE); PLASTIC PAVEMENT STRIPING (SOLID LINE)(12" WIDE); PLASTIC PAVEMENT STRIPING (SOLID LINE)(24" WIDE); ADJUST DRAIN CLEANOUT TO GRADE; REMOVE MANHOLES, CATCH BASINS, DROP INLETS, AND BACKFILL VOI; SIDEWALK, DRIVEWAY AND CURB SAW CUTTING; PAVEMENT SAW CUTTING ADJACENT TO EXISTING PAVEMENT AND AT PA; REMOVAL OF HANDICAP RAMPS, CURB AND GUTTER, AND CONCRETE SID; HANDICAP RAMPS, CURB AND GUTTER, AND CONCRETE SIDEWALKS AT I; YARD DRAIN SERVICE LINE 8" PVC; REHABILITATE EXISTING MANHOLE; 8" (PVC) NEW WATER MAIN WITH MAIN LINE FITTINGS INCLUDE TIE-; 8" NEW WATER MAIN WITH MAIN LINE FITTIGNS INCLUDING TIE-INS; 12" (PVC) NEW WATER MAIN WITH MAIN LINE FITTINGS INCLUDING T; NEW 8" VALVE; REPLACE 5/8" TO 1" WATER HOUSE CONNECTION (FROM MAIN TO METE; REPLACE 6" WATER HOUSE CONNECTION FROM MAIN TO METER); NEW WATER VALVE MANHOLE (4" THRU 12"); REMOVE MUD AND DEBRIS FROM INSIDE OF WATER METER BOX; ADJUST COMPETE WATER METER BOX TO GRADE; REPLACE BROKEN WATER METER BOX (5/8") TO (1"); PLUG EXISTING 4" TO 8" WATER MAIN AND FILL WITH FLOWABLE MAT; 16" (DUCTILE IRON) NEW WATER MAIN WITH MAIN LINE FITTINGS IN; NEW 6" VALVE; NEW FIRE HYDRANT; REPLACE 1-1/2" WATER HOUSE CONNECTION (FROM MAIN TO METER); REPLACE 2" WATER HOUSE CONNECTION (FROM MAIN TO METER); REPLACE 4" WATER HOUSE CONNECTION ( FROM MAIN TO METER); 8" WATER LINE OFFSET UP TO 24"; 8" WATER LINE OFFSET OVER 24"; 12" WATER LINE OFFSET UP TO 24"; 12" WATER LINE OFFSET OVER 24"; PLUG EXISTING 12" TO 16" WATER MAIN AND FILL WITH FLOWABLE M; REPAIR WATER MAIN WITH FULL CIRCLE CLAMP (PIPE SIZE 4" - 8"); REPAIR WATER MAIN WITH FULL CIRCLE CLAMP (PIPE SIZE 12" - 16; REPAIR WATER MAIN BY REMOVE AND REPLACE - MINIMUM LENGTH 4 F; REPAIR WATER MAIN BY REMOVE AND REPLACE - BEYOND LENGTH 10 F; REPAIR WATER MAIN BY REMOVE AND REPLACE - BEYOND 10 FT, MAXI; REPAIR WATER MAIN WITH BELL JOINT CLAMP (PIPE SIZE 4"-12"); REPAIR WATER MAIN WITH BELL JOINT CLAMP (PIPE SIZE 16"-24"); INSTALL SEWER MAINS (8", 6.1' - 8.0' DEPTH); INSTALL SEWER MANHOLE; NEW SEWER HOUSE CONECTION FROM MAIN TO BACK OF CURB; NEW SEWER HOUSE CONECTION BEYOND BACK OF CURB; ADJUST SEWER CLEANOUT TO GRADE; A-2000 PIPE 15" DIA; REMOVAL OF EXISTING OAK TREE AT STA 133 MONTEGUT AT TONTI; POWER POLE FOOTING AT STA133+00; PROVIDE LABOR AND MATERIAL TO DO TEST PITS AND PROOF ROLLING; INSTALL SEWER HOUSE CONNECTION FROM LINED MAIN TO PROPERTY L; REMOVE EXISTING 8" SEWER MAIN AND FILL VOID WITH SAND; REMOVE EXISTING WATER MAIN; INSTALL CASING ON FIRE HYDRANT LEAD GOING TOWARD RAILROAD TR; 8" NEW WATER MAIN WITH MAIN LINE FITTINGS INCLUDING TIE-INS; Sink Hole Repair on Port (force account); MODIFY THE EXISTING COMBO BOX TO ACCOMMODATE A ROLLOVER; 12" x 12" Drop Inlet; 10" A-2000 Pipe; Add Flowable Fill 18" RCP; Add Flowable Fill 15" RCP; Add CCTV Drain Lines; Add Cleaning CCTV Drain Lines; Yard drain service Line 4" PVC; Yard drain service Line 6" PVC