# Orleans Parish 14960

REMOVAL AND DISPOSAL OF EXISTING PORTLAND CEMENT CONCRETE PA; REMOVAL AND DISPOSAL OF EXISTING SIDEWALK, DRIVEWAY, FO...

**Recipient:** Hard Rock Construction, LLC

**Award Amount:** $2,066,272.45
**Ceiling:** $2,066,272.45

**Awarded:** December 31, 2020

**Identifier:** 14960

### Description

REMOVAL AND DISPOSAL OF EXISTING PORTLAND CEMENT CONCRETE PA; REMOVAL AND DISPOSAL OF EXISTING SIDEWALK, DRIVEWAY, FOOT LA; REMOVAL AND DISPOSAL OF EXISTING CURB (CONCRETE, ASPHALT, BR; REMOVAL AND DISPOSAL OF EXISTING ASPHALTIC CONCRETE PAVEMENT; ROADWAY EXCAVATION; UNSUITABLE SUBGRADE EXCAVATION AND SAND FILLING; GEOTEXTILE FABRIC FOR STABILIZATION; BASE COURSE; TRAFFIC MAINTENANCE AGGREGATE; COLD PLANING ASPHALTIC PAVEMENT (2.5" AVERAGE THICK); REINFORCED CONCRETE PAVEMENT (8&quot; THICK); CONCRETE MOUNTABLE CURB WITH DOWELS; GEOGRID; SIDEWALK, DRIVEWAY AND CURB SAW CUTTING; PAVEMENT SAW CUTTING ADJACENT TO EXISTING PAVEMENT AND AT PA; REMOVAL OF HANDICAP RAMPS, CURB AND GUTTER, AND CONCRETE SID; ADA-ACCESSIBLE CURB RAMPS, CURB AND GUTTER, AND CONCRETE SID; CONCRETE SIDEWALK (4&quot; THICK); CONCRETE DRIVEWAY (6" THICK); 2.5” THICK SUPERPAVE ASPHALTIC CONCRETE WEARING COURSE; 4.5” THICK SUPERPAVE ASPHALTIC CONCRETE BINDER COURSE; PLUG EXISTING WATER MAIN 4" THROUGH 12" AND FILL WITH FLOWAB; SINGLE VERTICAL CATCH BASIN REPAIR OR VERTICAL ADJUSTMENT RE; MANHOLE REPAIR OR VERTICAL ADJUSTMENT UP TO 6" REUSING EXIST; SIDEWALK TRANSITION ADJACENT TO HANDICAPPED RAMPS; TYPE-A DEAD END INSTALLATION; REINFORCED CONCRETE PIPE (12&quot;); REINFORCED CONCRETE PIPE (15&quot;); REINFORCED CONCRETE PIPE (18&quot;); REINF. CONCRETE WYE OR ARCH. EQUIV. - NEW (15&quot;X12&quot;; REINF. CONCRETE WYE OR ARCH. EQUIV. - NEW (18"X12"); NO.1 STANDARDARD DRAIN MANHOLE; TYPE 1 VERTICAL CATCH BASIN; 24"X30" CLEAR OPENING STANDARD DROP INLET; MOUNTABLE INLET; SODDING; ADJUST SEWER HOUSE CONNECTION; NO.2 STANDARDARD DRAIN MANHOLE; NO.3 STANDARDARD DRAIN MANHOLE; REINFORCED CONCRETE PIPE (24&quot;); REINFORCED CONCRETE PIPE (36&quot;); REINFORCED CONCRETE PIPE (27"); 8" PVC NEW WATER MAIN WITH MAIN LINE FITTINGS; 8" DUCTILE IRON NEW WATER MAIN WITH MAIN LINE FITTINGS; NEW 6" VALVE; NEW 8" VALVE; NEW FIRE HYDRANT; REPLACE 1-1/2" WATER HOUSE CONNECTION (FROM MAIN TO METER); REPLACE 5/8" TO 1'' WATER HOUSE CONNECTION WITH 1'' WATER; NEW WATER VALVE MANHOLE (4" THROUGH 12" VALVES); REPAIR WATER MAIN WITH FULL CIRCLE CLAMP (PIPE SIZE 4" - 8"; REPAIR WATER MAIN WITH BELL JOINT CLAMP (PIPE SIZE 4" - 12"); REPAIR WATER MAIN BY REMOVE AND REPLACE - MINIMUM LENGTH 4 F; REPAIR WATER MAIN BY REMOVE AND REPLACE - BEYOND 10 FT, MAXI; 8&quot; DUCTILE IRON NEW WATER MAIN WITH MAIN LINE FITTINGS; REPLACE 5/8&quot; TO 1&apos;&apos; WATER HOUSE CONNECTION; REMOVAL AND DISPOSAL OF EXISTING CURB AND GUTTER BOTTOM; CONCRETE MOUNTABLE CURB AND GUTTER BOTTOM; 27" SDR 35; REMOVE AND RESET 24" RCP; Tree Removal; PINE TREE REPLACEMENT; CB I MODIFICATION TO ROLLOVER; ADJUST WATER METER VALVE BOX; REPLACE BROKEN WATER METER BOX (5/8)&quot; TO (1&quot;); 4.5" THICK SUPERPAVE ASPHALTIC CONCRETE BINDER COURSE
