# Orleans Parish 17294

REMOVAL AND DISPOSAL OF EXISTING PORTLAND CEMENT CONCRETE PA; REMOVAL AND DISPOSAL OF EXISTING SIDEWALK, DRIVEWAY, FO...

**Recipient:** FLEMING CONSTRUCTION CO.,INC.

**Award Amount:** $8,466,381.06
**Ceiling:** $8,466,381.06

**Awarded:** December 31, 2020

**Identifier:** 17294

### Description

REMOVAL AND DISPOSAL OF EXISTING PORTLAND CEMENT CONCRETE PA; REMOVAL AND DISPOSAL OF EXISTING SIDEWALK, DRIVEWAY, FOOT LA; REMOVAL AND DISPOSAL OF EXISTING CURB AND GUTTER BOTTOM; REMOVAL AND DISPOSAL OF EXISTING ASPHALTIC CONCRETE PAVEMENT; ROADWAY EXCAVATION; UNSUITABLE SUBGRADE EXCAVATION AND SAND FILLING; GEOTEXTILE FABRIC FOR STABILIZATION; GEOGRID; BASE COURSE; TRAFFIC MAINTENANCE AGGREGATE; 2.5” THICK SUPERPAVE ASPHALTIC CONCRETE WEARING COURSE; 4.5” THICK SUPERPAVE ASPHALTIC CONCRETE BINDER COURSE; COLD PLANING ASPHALTIC PAVEMENT (2.5&quot; AVERAGE THICK); REINFORCED CONCRETE PAVEMENT (8&quot; THICK); CONCRETE SIDEWALK (4&quot; THICK); CONCRETE DRIVEWAY (6&quot; THICK); CONCRETE MOUNTABLE CURB WITH DOWELS; 6" CONCRETE BARRIER CURB WITH DOWELS; CONCRETE MOUNTABLE CURB AND GUTTER BOTTOM; SIDEWALK, DRIVEWAY AND CURB SAW CUTTING; PAVEMENT SAW CUTTING ADJACENT TO EXISTING PAVEMENT AND AT PA; REMOVAL OF HANDICAP RAMPS, CURB AND GUTTER, AND CONCRETE SID; ADA-ACCESSIBLE CURB RAMPS, CURB AND GUTTER, AND CONCRETE SID; ROOT PRUNING; SIDEWALK TRANSITION ADJACENT TO HANDICAPPED RAMPS; SURFACE APPLIED TACTILE / DETECTABLE WARNING SURFACE TILES; VERTICAL CATCH BASIN COVER; VERTICAL CATCH BASIN FRAME; SINGLE VERTICAL CATCH BASIN REPAIR OR VERTICAL ADJUSTMENT RE; DOUBLE VERTICAL CATCH BASIN REPAIR OR VERTICAL ADJUSTMENT RE; SINGLE COMBINATION VERTICAL CATCH BASIN MANHOLE (8319-D); TIMBER CURB; TYPE-A DEAD END INSTALLATION; MANHOLE COVER; MANHOLE FRAME; MANHOLE REPAIR OR VERTICAL ADJUSTMENT UP TO 6" REUSING EXIST; MANHOLE REPAIR OR VERTICAL ADJUSTMENT OVER 6" BRICK WORK ONL; REINFORCED CONCRETE PIPE (12"); REINFORCED CONCRETE PIPE (15"); REINFORCED CONCRETE PIPE (18"); REINFORCED CONCRETE PIPE (24"); REINFORCED CONCRETE PIPE (30"); REINFORCED CONCRETE PIPE (36"); REINFORCED CONCRETE ARCH PIPE (22x13); REINFORCED CONCRETE ARCH PIPE (29x18); REINFORCED CONCRETE ARCH PIPE (36x23); REINFORCED CONCRETE ARCH PIPE (44x27); REINFORCED CONCRETE ARCH PIPE (51x31); REINFORCED CONCRETE ARCH PIPE (58x36); REINFORCED CONCRETE ARCH PIPE (65x40); REINFORCED CONCRETE ARCH PIPE (73x45); PVC YARD DRAIN SERVICE LINE(8"); NO.1 STANDARD DRAIN MANHOLE; NO.2 STANDARD DRAIN MANHOLE; NO.3 STANDARD DRAIN MANHOLE; SPECIAL DRAIN MANHOLE -3937; TYPE C CATCH BASIN ADJUSTMENT; NO. 1 STANDARD CATCH BASIN; DOUBLE NO.1 STANDARD CATCH BASIN; SINGLE MOUNTABLE CATCH BASIN; POINT REPAIR OF EXISTING DRAINLINES UP TO 10 FEET (12"); POINT REPAIR OF EXISTING DRAINLINES UP TO 10 FEET (15"); POINT REPAIR OF EXISTING DRAINLINES UP TO 10 FEET (18"); POINT REPAIR OF EXISTING DRAINLINES UP TO 10 FEET (21"); POINT REPAIR OF EXISTING DRAINLINES UP TO 10 FEET (30"); CCTV INSPECTION OF MAIN STORM SEWER LINES AND LATERALS, INCL; CLEANING OF MAIN STORM SEWER LINES AND LATERALS, INCLUDING D; HEAVY CLEANING OF MAIN STORM SEWER LINES AND LATERALS, INCLU; REINFORCED CONCRETE PAVEMENT (8" THICK); CONCRETE SIDEWALK (4" THICK); CONCRETE DRIVEWAY (6" THICK); 8" PVC NEW WATER MAIN WITH MAIN LINE FITTINGS; 8" DUCTILE IRON NEW WATER MAIN WITH MAIN LINE FITTINGS; 12" PVC NEW WATER MAIN WITH MAIN LINE FITTINGS; 12” DUCTILE IRON NEW WATER MAIN w/MAIN LINE FITTINGS; NEW 6" VALVE; NEW 8" VALVE; NEW 12" VALVE; NEW FIRE HYDRANT; REPLACE 5/8" TO 1'' WATER HOUSE CONNECTION WITH 1'' WATER; 8" WATER LINE OFFSET UP TO 24"; 8" WATER LINE OFFSET OVER 24"; 12” WATER LINE OFFSET UP TO 24”; 12” WATER LINE OFFSET OVER 24”; NEW WATER VALVE MANHOLE (4" THROUGH 12" VALVES); REMOVE MUD AND DEBRIS FROM INSIDE OF WATER METER BOX; ADJUST COMPLETE WATER METER BOX TO GRADE; REPLACE BROKEN WATER METER BOX (5/8") TO (1"); PLUG EXISTING WATER MAIN 4" THROUGH 12" AND FILL WITH FLOWAB; REPLACE 1-1/2" WATER HOUSE CONNECTION (FROM MAIN TO METER); REPAIR WATER MAIN WITH FULL CIRCLE CLAMP (PIPE SIZE 4" - 8"; REPAIR WATER MAIN WITH FULL CIRCLE CLAMP (PIPE SIZE 12" - 16; REPAIR WATER MAIN WITH BELL JOINT CLAMP (PIPE SIZE 4" - 12"); REPAIR WATER MAIN WITH BELL JOINT CLAMP (PIPE SIZE 16" - 24"; REPAIR WATER MAIN BY REMOVE AND REPLACE - MINIMUM LENGTH 4 F; REPAIR WATER MAIN BY REMOVE AND REPLACE - BEYOND 10 FT, MAXI; INSTALL SEWER MAINS 8" (6.1' - 8.0'); INSTALL SEWER MAINS 8" (8.1' - 10.0'); INSTALL SEWER MAINS (8") (10.1'-14' DEPTH); INSTALL SEWER MAINS (12") (12.1'-14' DEPTH); INSTALL SEWER MANHOLE; NEW SEWER HOUSE CONNECTIONS FROM MAIN TO BACK OF CURB (6"); RE-CONNECT EXISTING SEWER HOUSE CONNECTION TO NEW MAIN AND E; REPLACE EXISTING SEWER HOUSE CONNECTION BEYOND BACK OF CURB; ADJUST SEWER HOUSE CONNECTION; CUT LINER TO RESTORE EXISTING SEWER HOUSE CONNECTION; 6" WATER LINE OFFSET UP TO 24"; 10" DUCTILE IRON CASING; REINFORCED CONCRETE ARCH PIPE (65X40); 8" DUCTILE IRON WATER MAIN W/ MAIN LINE FITTINGS; REMOVE AND REPLACE 6" LEAKING WATER VALVE AND NEARBY PIPE AS; 4.5â%E2%82%AC%C2%9D THICK SUPERPAVE ASPHALTIC CONCRETE BINDE
